4 normal configuration setup parameters, Jxxyyzz<cr, Table 3-7. configuration setup parameters – Rice Lake Condec UMC600 User Manual

Page 22: Configuration 19

Advertising
background image

Configuration

19

3.1.4

Normal Configuration Setup Parameters

You must be in the configuration mode (SW1-2 closed to set the indicator from the PC) to be able to write
configuration parameters. To write commands the following

Jxxyyzz<CR>

sequence must be used. The following

parameters and their setup numbers are as follows:

Parameter 1 = Grads

J0600 03 = Both

J1100 02 = Ov.Un

J1103 06 = 6

J1200 14 = 50

J0100 00 = 500

J1101 00 = HL

J1103 07 = 7

J0100 01 = 1000

Parameter 7 = AZM Capture

J1101 01 = TGT

J1103 08 = 8

Parameter 13 = Truck in/out

J0100 02 = 1500

J0700 00 = Off

J1103 09 = 9

J1300 00 = Nor

J0100 03 = 2000

J0700 01 = .5

J1102 00 = Pos

J1103 10 = 10

J1300 01 = Tru

J0100 04 = 2500

J0700 02 = 1

J1102 01 = Zer

J1301 00 = Can

J0100 05 = 3000

J0700 03 = 3

J1103 00 = Off

J1301 01 = Str

J0100 06 = 4000

J1103 00 = Pos

J1103 01 = 1

J0100 07 = 5000

Parameter 8 = Zero Range

J1103 01 = Zer

J1103 02 = 2

J1302 00 = Off

J0100 08 = 6000

J0800 00 = 1.9

J1103 03 = 3

J1302 01 = On

J0100 09 = 8000

J0800 01 = FS

J1104 00 = Pos

J1103 04 = 4.

J0100 10 = 10000

J1104 01 = Zer

Parameter 14 = Serial

J0100 11 = 12000

Parameter 9 = Motion Band

J1104 00 = Off

J1400 00 = Off

J0100 12 = 14000

J0900 00 = Off

J1100 03 = Bat 1

J1104 01 = S1

J1400 01 = SI

J0100 13 = 16000

J0900 01 = 1

J1101 00 = Off

J1104 02 = S1.P

J1400 02 = DU

J0100 14 = 18000

J0900 02 = 3

J1101 01 = S1

J1104 03 = S1.D

(J1401 – 1405 for SI and DU)

J0100 15 = 20000

J0900 03 = 5

J1101 02 = S1.P

J1104 04 = S.P.D.

J1401 00 = Net

J0900 04 = 10

J1101 03 = S1.D

J1401 01 = GTN

Parameter 2 = Resolution

J1101 04 = S.P.D.

J1105 00 = Pos

J0200 00 = 1

Parameter 10 = Units

J1105 01 = Zer

J1402 00 = Off

J0200 01 = 2

J1000 00 = Lb only

J1102 00 = Pos

J1402 01 = 1

J0200 02 = 5

J1000 01 = Kg only

J1102 01 = Zer

J1106 00 = Off

J1402 02 = 2

J0200 03 = 10

J1000 02 = Lb/Kg Conversion

J1106 01 = 1

J1402 03 = 3

J0200 04 = 20

J1103 00 = Off

J1106 02 = 2

J1402 04 = 4

J0200 05 = 50

Parameter 11 - Setpoints

J1103 01 = S2

J1106 03 = 3

J0200 06 = 100

J1100 00 = Off

J1103 02 = S2.P

J1106 04 = 4.

J1403 00 = Off

J1100 01 = SP

J1103 03 = S2.D

J1106 05 = 5

J1403 01 = Co

Parameter 3 = Decimal Point

J1101 00 = Off

J1103 04 = S.P.D.

J1106 06 = 6

J1403 02 = De

J0300 00 = 0

J1101 01 = S1

J1106 07 = 7

J0300 01 = 0.0

J1101 02 = S1.P

J1104 00 = Pos

J1106 08 = 8

J1404 00 = 3

J0300 02 = 0.00

J1101 03 = S1.D

J1104 01 = Zer

J1106 09 = 9

J1404 01 = 6

J0300 03 = 0.000

J1101 04 = S.P.D.

J1106 10 = 10

J1404 02 = 12

J0300 04 = 0.0000

J1100 04 = Bat2

J1404 03 = 24

J1102 00 = Pos

J1101 00 = Off

Parameter 12 = Zero Band

J1404 04 = 48

Parameter 5 = Digital Averaging

J1102 01 = Zer

J1101 01 = S1

J1200 00 = Off

J1404 05 = 96

J0500 00 = 1

J1101 02 = S1.P

J1200 01 = 1

J0500 01 = 2

J1103 00 = Off

J1101 03 = S1.D

J1200 02 = 2

J1405 00 = Off

J0500 02 = 4

J1103 01 = S2

J1101 04 = S.P.D.

J1200 03 = 3

J1405 01 = Co

J0500 03 = 8

J1103 02 = S2.P

J1200 04 = 4

J1405 02 = De

J0500 04 = 16

J1103 03 = S2.D

J1102 00 = Pos

J1200 05 = 5

J0500 05 = 32

J1103 04 = S.P.D.

J1102 01 = Zer

J1200 06 = 6

(J1406 for SI only)

J0500 06 = A1

J1103 05 = tol.

J1200 07 = 7

J1406 00 = 3

J0500 07 = A2

J1103 00 = Off

J1200 08 = 8

J1406 01 = 6

J1104 00 = Pos

J1103 01 = 1

J1200 09 = 9

J1406 02 = 12

Parameter 6 = Tare

J1104 01 = Zer

J1103 02 = 2

J1200 10 = 10

J1406 03 = 24

J0600 00 = ATNR

J1103 03 = 3

J1200 11 = 20

J1406 04 = 48

J0600 01 = Auto

J1103 04 = 4.

J1200 12 = 30

J1406 05 = 96

J0600 02 = FT

J1103 05 = 5

J1200 13 = 40

Table 3-7. Configuration Setup Parameters

Advertising