2 macro file setup – Rice Lake Condec UMC600 User Manual

Page 38

Advertising
background image

Options Configuration

35

4.7.2

Macro File Setup

There may be times when you need to print more than the 30 character codes that are allowed in the custom transmit
files (7.1 - 7.8). To do custom transmits larger than 30 character codes, the UMC600 provides eight “macro” files
(7.9 to 7.16) that can be called in from the custom transmit files. This is done by putting a parameter code of 600,
601, 602, 603, 604, 605, 606, or 607 in your custom transmit file to macros 7.9 through 7.16 respectively. As with
the custom transmit files, each macro file can contain up to 30 character codes. You can call more than one macro in
your custom transmit or even call the same macro more than once.

Each macro file holds up to 30 ASCII characters and parameter codes. Refer to the ASCII characters and Table 9-2
in Section 9 for parameter codes.

Table 4-11. Print File Definition Codes

Table 4-12. Code 600 Definitions

Table 4-13. Code 601 Definitions

Print File 7.1 – Port 1 gross mode data

Line #

Code

Code definition

01

002

STX start of text

02

600

* macro file #1 (7.9)

03

200

gross weight with lb/kg gr

04

032

SP (space)

05

601

* macro file #2 (7.10)

06

013

CR (carriage return)

07

010

LF (line feed)

08

999

end of file

Code 600 – macro file 7.9

Line #

Code

Code definition

01

065

A character

02

067

C character

03

032

SP (space)

04

105

i character

05

110

n character

06

099

c character

07

046

. (period)

08

013

CR (carriage return)

09

010

LF (line feed)

10

999

end of file

Code 601 – macro file 7.10

Line #

Code

Code definition

01

402

date per setup

02

032

SP (space)

03

401

time per setup

04

999

end of file