Avaya EA401 User Manual

Page 8

Advertising
background image

Avaya Inc.

Installation and Operation

Model EA401

Page 8


Wiring For Tip & Ring

• After mounting the telephone follow these steps.

• Run tip, ring and ground wires from the local exchange into the lower junction

box. The tip and ring wires must not be connected to the local exchange until
installation is completed. A sealing fitting must be installed within 45.7 cm
(18") on the exchange side of the lower junction box.

See: Figure 4 - Lower
Junction Box Wiring

• Attach the tip and ring wires to the orange and blue wires from telephone

using twist on wire connectors. Attach #10 ring lugs to the end of the three
green wires and attach these wires to the ground screw in the junction box.

• For tone (DTMF) dialing operation of the telephone, connect the two brown

wires together and protect the connection with a twist-on wire connector. For
pulse dialing operation of the telephone, separate the two brown wires and
insulate the ends to prevent accidental contact with the interior of the junction
box.

• Check the wiring and close the junction box.



Figure 4 - Lower Junction Box Wiring


FROM EXCHANGE

GROUND

TONE/PULSE: CONNECT

WIRES AND KEEP WIRES

ISOLATED

RING

TIP

(BROWN)

TONE/PULSE SWITCH

GROUND (GREEN)

NOT POLARITY SENSITIVE

(BLUE & ORANGE)

TIP & RING

TO EA401

Advertising