A-4

INSTALLATION

PRO-CUT 25

A-4

NOTE: When using nitrogen gas from a cylinder, the

cylinder must have a pressure regulator.

Maximum psi from a nitrogen gas cylinder to
the PRO-CUT 25 regulator should never
exceed 150 psi.

Install a hose between the nitrogen gas
cylinder regulator and the PRO-CUT 25
gas inlet

.
CYLINDER could explode if damaged.

• Keep cylinder upright and chained to a fixed support.

• Keep cylinder away from areas

where it could be damaged.

• Never lift machine with cylinder

attached.

Never allow the cutting torch to touch the
cylinder.

Keep cylinder away from live electrical
parts.

Maximum inlet pressure 150 psi.

__________________

OUTPUT CONNECTIONS

Torch

The PRO-CUT 25 is sent from the factory with a 15’
PCT 20 cutting torch installed. Additional cutting torch-
es can be ordered from the K1615 series. Hand-held
torches come with 15' or 25’ cables.

Read and understand this entire section before oper-
ating the machine.

WARNING