PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

The Pro-Cut powers up properly but
there is no response when the trig-
ger is pulled and only the POWER
LED is lit.

1. Press Purge button on the front of

the Pro-Cut. If air does not flow,
then:

a. Reconnect Board may be

faulty.

b. The main gas solenoid assem-

bly may be faulty. Check or
replace.

c. Possible faulty Control board.

2. Remove the handles (or barrel) of

the torch and examine all the con-
nections. Pay attention to location
of electrode lead mounting at back
of torch head, broken trigger and
solenoid leads.

3. Check for proper trigger switch

operation. Remove the torch cable
assembly from the Pro Cut and
test for continuity between 1 and 2
at the Green 4 Pin Connector
when the trigger switch is
depressed and no continuity when
the switch is not depressed.
Replace the trigger switch or torch
cable if defective.

4. Possible faulty Control board.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.