Installation – Lincoln Electric IM665 PRO-CUT 25 User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

A-1

Weight

Including

Torch Cable

35 lbs.

15.9 kg.

INPUT - SINGLE PHASE / 60 HERTZ ONLY

RATED OUTPUT

OUTPUT

RECOMMEND INPUT WIRE AND FUSE SIZES

REQUIRED GAS FLOW RATE

REQUIRED GAS INLET PRESSURE

PHYSICAL DIMENSIONS

TECHNICAL SPECIFICATIONS - PRO-CUT 25 (K1756-1)

Standard Voltage

Duty Cycle

20% on 115 V
60% on 115 V

100% on 230 V

35% on 115 V

60% on 230 V

Current

Range

12-25 Amps

AC Input

Voltage

at

50/60

Hertz

230V-1Ø

115V-1Ø
115V-1Ø
115V-1Ø

Fuse

(Super Lag)

Circuit Breaker

(Delay Type)

20 AMPS

15 AMPS
20 AMPS
30 AMPS

#14 (2.5 mm

2

)

#12 (4 mm

2

)

#12 (4 mm

2

)

#12 (4 mm

2

)

2 Input Supply Wires 1 Ground Wire

#14 (2.5 mm

2

)

#12 (4 mm

2

)

#12 (4 mm

2

)

#12 (4 mm

2

)

Type 75

o

C

Copper Wire in Conduit

AWG (IEC) Sizes

Depth

16.1 in.

410 mm

Width

6.3 in.

160 mm

Height

10.2 in.

260 mm

Open Circuit

Voltage

400 VDC

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30

o

C or Less

Pilot Current

12 Amps

AMPS

15 A
20 A
20 A
25 A
25 A

1Ø Input Current at Rated Output

115/230/1/50/60Hz

115 V : 15 A @ 20%
115 V : 26.7A@ 60%
115 V : 37.7A@ 35%
230 V : 15 A@100%
230 V : 19 A @ 60%

55 PSI @ 240 SCFH

( 3.8 Bar. @ 6800 LHR)

65 to 150 PSI

(4.5 Bar. TO 10.3 Bar.)

25 A

15 A
20 A
25 A

Output

Input Cord

Plug

Size

6-20P or 6-30P or 6-50P

5-15P* or 5-20P* or 5-30P or 5-50P

5-20P* or 5-30P or 5-50P

5-30P or 5-50P

* Included with machine

PRO-CUT 25

Advertising