SoleusAir SE-PAC-08E9 User Manual

Page 13

Advertising
background image

13

3) Press the MODE button until the fan mode icon light up on the control panel display.
4) Select the fan speed by pressing the FAN button by using the Remote control.

NOTE: It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan
mode.


Auto Mode
1) Install the exhaust hose and window kit properly (see pages 7 & 8 ).
2) Plug the Power Cord into an electrical outlet.
3) Turn on the unit by pressing the POWER button.
4) Press the MODE button on the remote control until the AUTO appears on the remote control LCD

panel display.

NOTE: During AUTO mode, the unit operates in FAN mode when the room temperature is below 68

°

F,

Dehumidifier mode when the room temperature is between 68

°

F to 80

°

F. And Air Conditioner mode

CONDENSATE EVAPORATION

Emergency Condensate Holding Tank

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emer-
gency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automati-
cally shut off and the led of BUCKET FULL will light up on the control panel display. To empty the con-
densate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately
1” high to catch the water coming out of the condensate tank. Connect the supplied drainage hose to the
back of the unit to aid in drainage into the pan. Once the condensate tank is drained, the unit will begin
working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. An-
other option is to purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the
back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not ad-
vised to use continuous drainage when the room temperature is higher than 90

°

F .


If you do not need the emergency tank emptied immediately simply leave the unit on. The fan in your air
conditioner will continue to run to help evaporate the moisture as fast as possible.


To resume operation quickly, empty the water container according to the following steps:
1. Turn the unit off. Do not move the unit when the water container is full.
2. Place the drain pan accessory under the drainage port at the back of the unit.
3. Remove the rubber plug from the drain hole. The condensate water will drain out automatically.
4. When the drain pan is full, install the rubber plug back onto the drainage hole to stop the water flow.
5. Empty the drain pan.
6. Repeat steps 2-5 until all the water is emptied.

NOTE: Once the water container has
been emptied, install the rubber plug
back onto the drain hole. It is not advised
to use continuous drainage when the
room temperature is higher than 90

°

F .

Drain Hole

Rubber Plug