Spectra Precision Survey Pro v3.80 Recon GPS User Manual User Manual

Page 56

Advertising
background image

GPS User’s Manual

52

Note: Raw data types

+ Rx Raw

(and/or

+ OBN

for Ashtech users) are

only available when

Receiver Dynamics

is set to

Static on occupy

.

Note: All receivers need to be in static mode to record Rx. Raw, and
some receivers always record Rx Raw when in static mode. If the
combination of settings you select is not compatible for your receiver,
you will be prompted to change the settings.

.

4.

Select the

Accept

filter.

¾

Fixed RTK only

will reject all positions that are not fixed.

Code, Float, or Fix

will allow you to accept any position

accept autonomous or invalid data.

Note: If you are collecting simultaneous RTK and post processing
data, you can accept an autonomous position based on the
Job/Settings, Post Process card. If enabled, you will either be
prompted to put the autonomous position on a separate layer, or it
will automatically be stored on a separate layer.

5.

Set the

Acceptance Criteria

.

¾

Acceptance

Criteria

is used to check each solution you

accept. If the measurement exceeds the criteria, you will
be prompted to accept or reject the point. Check this box
if you want to enable criteria checking. Enter a maximum
value for HRMS, VRMS, and/or PDOP in the fields. Only
fields with a non-zero value will be used for criteria
checking.

¾

To accept data points automatically using the selected
criteria, check the

Auto Accept

box at the bottom of this

page.

6.

Tap

2. to return to the Data Collection screen.

Advertising