system are used (such as a dishwasher or washing machine). If

hydrogen gas is present, there will probably be an unusual sound

similar to air escaping through the pipe as the hot water faucet

is opened. There must be no smoking or open flame near the

faucet at the time it is open.
high water temperature shut off system
This water heater is equipped with an automatic reset type high

limit (energy Cutoff) sensor. The high limit switch interrupts

the main burner gas flow should the water temperature reach

203°F (95°C).
The high limit will automatically reset when the water temperature

drops below 120°F (49°C). After cooling the tank temperature,

turn off the water heater for at least 10 seconds by using the

switch on front of the control box. Turn on the water heater. If

this fails to correct the problem, contact your plumber or service

representative.

further information regarding anode replacement and this

chlorination treatment.
If the smelly water persists after the anode replacement and

chlorination treatment, we can only suggest that chlorination or

aeration of the water supply be considered to eliminate the water

problem.
Do not remove the anode leaving the tank unprotected. By doing

so, all warranty on the water heater tank is voided.
“air” in hot water faucets
hyDrOGeN GAS: hydrogen gas can be produced in a hot

water system that has not been used for a long period of time

(generally two weeks or more). hydrogen gas is extremely

flammable and explosive. To prevent the possibility of injury

under these conditions, we recommend the hot water faucet,

located farthest away, be opened for several minutes before

any electrical appliances which are connected to the hot water