Plumbing – Airstream NTERSTATE User Manual

Page 65

Advertising
background image

G

G - 5

PLUMBING

WATER PUMP AND STRAINER

Manufacturer:

Shur-Flo

1740 Markle Street

Elkhart, Indiana 46514

Phone: 219-294-7581

The water pump and strainer are located inside the

rear cargo door on the Rear Bath Model. The Mid Bath

model has the pump under the galley and can be ac-

cessed by opening the lower galley door. The strainer

should be visually checked for accumulation of sand

or debris that could affect water flow.

To clean the strainer

screen, first remove

the inlet connection

from the pump side

of strainer. This will

allow the intake

side of the strainer

to be rotated about

1/8 turn counter

clockwise and be

removed. The screen part of the strainer will now be

accessible for cleaning.

When reassembling only rotate the inlet side of the

strainer until the stops are felt. The “O” ring performs

the sealing and too much pressure will only break

the strainer.

CAUTION

: The Sureflo water pump should be

turned off when hooked to city water.

SANITIZING

Potable water systems require periodic maintenance

to deliver a consistent flow of fresh water. Depending

on use and the environment the system is subject to,

sanitizing is recommended prior to storing and before

using the water system after a period of storage.

Systems with new components, or ones that have been

subjected to contamination, should also be disinfected

as follows:

1. Use one of the following methods to determine the

amount of common household bleach needed to

sanitize the tank.

A) Multiply “gallons of tank capacity” by

0. 13; the result is the ounces of bleach

needed to sanitize the tank.

B) Multiply “Liters of tank capacity” by 1.0;

the result is the milliliters of bleach needed

to sanitize the tank.

2. Mix into solution the proper amount of bleach within

a container of water.

3. Pour the solution (water/bleach) into the tank and fill

the tank with potable water.

4. Open all faucets (Hot & Cold) allowing the water to

run until the distinct odor of chlorine is detected.

5. The standard solution must have four (4) hours of

contact time to disinfect completely. Doubling the

solution concentration will allow for contact time of

one (1) hour.

6. When the contact time is completed, drain the tank.

Refill with potable water and purge the plumbing of

all sanitizing solution.

NOTE: The sanitizing procedure outlined above is in

conformance with the approved procedures of RVIA

ANSI A 119.2 and the U.S. Public Health Service.

Intake

Strainer

Turn Intake Counter-
Clockwise to remove

Water Pump

Advertising