Plumbing, Turn stem 1/2 turn notched flat on stem – Airstream NTERSTATE User Manual

Page 68

Advertising
background image

G

PLUMBING

G - 8

GALLEY FAUCET

SERVICE

CAUTION

: Always turn water OFF before remov-

ing existing faucet or disassembling the valve. Open

faucet handle to relieve water pressure and ensure that

complete water shutoff has been accomplished.

1. Remove red/blue plug bottom (3) from front of

lever handle, remove screw (2) and lever handle

(1). Unscrew handle screw (4) and lift off the handle

adapter (5) (with handle connector (6) attached).

2. Unscrew collar (9) being careful not to damage

the finish, lift out pivot retainer (10). Unscrew the

retainer nut using channel locks and remove the

O-ring (12) and bearing washer (13). Remove wash-

ers (7) and (8) from the cartridge stem

3. Pry out retainer clip (14) with flat bladed screwdriver.

4. Grasp cartridge stem with a pair pliers and pull

cartridge (15) straight up and out of body.

Reinstall has follows: Install cartridge (15) into valve

body with notched flat on stem facing forward. Be sure

to position the ears of the cartridge in the front and

back. Reinstall the retainer clip (14) that straddles the

ears on the cartridge. Continue reassembly by revers-

ing the steps discussed in steps 1-3.

Note: To service vacuum breaker assembly, (anti-si-

phon protection) the hose must be disconnected from

the threaded discharge prior to removing the spout

receptor (20).

To Correct reversed Hot and Cold Positions:

(It is necessary to shut off water supplies)

1. Position handle so that it points toward you.

Remove handle (follow instructions for SERVICE

step 1 only).

2. Turn cartridge stem so that the notch is turned ½

turn or 180 degrees.

3. Reinstall handle following SERVICE instructions.

1

2

3

4

7

15

15

5

4

8

12

9

13

3

10

14

11

20

2

1

Ear

Clip

Notch

Turn Stem

1/2 Turn

Notched Flat

on stem