HT instruments HT4010 User Manual

Page 37

Advertising
background image

HT4010

EN - 16

6.1.1 Safety
Comply with:

IEC/ENEN 61010-1

Insulation: Double

insulation

Pollution: Level

2

For inside use, max height: 2000m (6562 ft)
Installation category:

CAT III 600V to ground


6.1.2 General

data

Mechanical characteristics
Size:

197(L) x 70(W) x 40(H)mm ; 8 (L) x 3(W) x 2(H) inches

Weight (including battery): about 183g (6 ounces)
Max conductor size:

30mm


Supply
Battery type:

1x9V alkaline battery NEDA 1604 IEC 6F22

Low battery indication:

“BAT” is displayed when the battery level is too low

AutoPowerOFF after

about

15min


Display
Characteristics:

3½ LCD with maximum reading 2000 points plus decimal
point, unit symbol indication and backlight

Sample rate:

2 times/sec

Conversion mode:

Mean value


6.2 ENVIRONMENTAL

CONDITIONS

6.2.1 Climatic

conditions

Reference temperature:

23° ± 5°C (73°F ± 41°F)

Operating temperature:

5 ÷ 40°C (41°F ÷ 104°F)

Operating humidity:

<80%RH

Storage temperature:

-20 ÷ 60 °C (-4°F ÷ 140°F)

Storage humidity:

<80%RH


This product conforms to the prescriptions of the European directive on low voltage

2006/95/EEC and to EMC directive 2004/108/EEC

6.3 ACCESSORIES
6.3.1 Standard

accessories

The content of a standard package is the following:
• Instrument

HT4010

• Test leads - Cod. KIT4000A

• Carrying

bag

• Battery

• User

manual

Advertising