EN - 9

4.3.2. DC Voltage measurement

CAUTION

Maximum input for DC Voltage measurements is 1000V. Do not take any
voltage measurement exceeding this limit in order not to risk electrical
shock or damaging the tester.

Fig. 4: Taking DC voltage measurements

1. Rotate the switch on position
2. Insert the red test lead plug into V

CAPHz%Temp

jack and the black test lead

plug into COM jack (Fig. 4)

3. Connect the two long ends of test leads to the desired circuit, then reading will be

displayed

4. When “O.L." symbol is displayed, the result is over the maximum value that the

instrument is able to measure

5. For HOLD, MAX/MIN and REL features please refer to § 4.2

CAUTION

• Due to the high input impedance is possible that the meter performs the

zero of the display taking longer

• The possible blinking values shown at display with open input terminals

are not a problem of the meter

and these values will not be added to

the measured value