Caution – HT instruments HT9015 User Manual

Page 11

Advertising
background image

HT9014 - HT9015

EN - 10

4.3.3. Resistance measurement

CAUTION

Before taking any in circuit resistance measurement, remove power from
the circuit to be tested and discharge all the capacitors.

Fig. 5: Taking Resistance measurement


1. Rotate the switch on

CAP

position

2. Insert the red test lead plug into V

CAPHz%Temp

jack and the black test lead

plug into COM jack (Fig. 5)

3. Connect the two long ends of test leads to the desired circuit, then reading will be

displayed

4. When “O.L.” symbol is displayed, the result under test exceeds the maximum value

that the instrument is capable of measuring

5. For HOLD and MAX/MIN features please refer to § 4.2