EN - 20

6.1.1. Safety
Comply with:

IEC/EN 61010-1

Insulation: double

insulation

Pollution degree:

2

Max height of use:

2000m (6562 ft)

Installation category:

CAT IV 600V, CAT III 1000V to ground

6.1.2. General data
Mechanical characteristics
Dimensions (L x W x H):

215 x 74 x 43mm ; 8 x 3 x 2 in

Weight (including battery):

285g (10 ounces)

Max conductor size:

30mm (1in)

Supply
Battery type:

1 battery 9V NEDA 1604 IEC 6F22 JIS 006P.

Low battery indication:

” is displayed when the battery level is low

Battery life:

about 200 hours

AutoPowerOff: after

15

minutes

of idleness (not disabled)

Display
Characteristics:

4 LCD (max 6000 counts), decimal point, unit symbol
indication, bargraph and backlight

Sample rate:

2 times/sec

Conversion mode:

TRMS

6.2. ENVIRONMENTAL CONDITIONS
6.2.1. Climatic conditions
Reference temperature:

18°C

÷ 28°C (65°F ÷ 83°F)

Operating temperature:

5 ÷ 40 °C (41°F ÷ 104°F)

Operating humidity:

<80%RH

Storage temperature:

-20 ÷ 60 °C (-4°F

÷ 140°F)

Storage humidity:

<80% RH

This product conforms to the prescriptions of the European directive on low voltage

2006/95/EEC and to EMC directive 2004/108/EEC

6.3. STANDARD ACCESSORIES

• Test leads – Code 4413-2

• Adapter + type K bead probe

• Carrying

bag

• Battery

• User

manual

6.4. OPTIONAL ACCESSORIES
The herewith type K probes are avaliable:

Model Description

Temperature

range

Accuracy

(at 100°C)

Probe length

(mm)

Probe diameter

(mm)

TK107

Air and gas
temperature

-40

÷ 800 °C

± 2.2rdg

200

1.5

TK108

Inner temperature of
semisolid
substances

-40

÷ 800 °C

± 2.2rdg

200 3

TK109

Inner temperature of
fluids

-40

÷ 800 °C

± 2.2rdg

200 4

TK110

Surface temperature -40

÷ 400 °C

± 2.2rdg

200 5

TK111

Surface temperature
with fixed tip at 90°

-40

÷ 400 °C

± 2.2rdg

260 5

Advertising