Mpp300, En - 14 – HT instruments MPP300 User Manual

Page 16

Advertising
background image

MPP300

EN - 14

32. To stop testing, press the GO/STOP key on instrument

SOLAR I-V and confirm with ENTER that you want to stop
recording

33. The display of SOLAR I-V will show the message “DATA

DOWNLOAD” to indicate that the data will be transferred to
the main unit during its various phases

34. After the automatic data transfer phase, the instrument:

 Do not show any results if do not exist on the PV

installation a “stable irradiance” condition more than the
minimum irradiance threshold (see see user’s manual of
MASTER instrument) or all PRp values are not valid (PRp
> 1.15).

 Display the best performance values if during the

recording, the Irradiance values reached the “stable
condition and its values were higher than the minimum
irradiance threshold (see user’s manual of MASTER
instrument).

35. Press SAVE to save the results or ESC to exit the screen of

the results and go back to the initial screen

15/05/10 15:35:00

P R p

0 . 8 2

I r r

9 7 1

W / m 2

P n o m 3 . 5 0 0

k W

T c

4 5 . 1

° C

T e

3 0 . 5

° C

P d c

3 . 1 2 5

k W

P a c

2 . 9 6 0

k W

n d c

0 . 8 6

n a c

0 . 9 5

A n a l y s i s R e s u l t

Select

M P P


Advertising