HT instruments MPP300 User Manual

Page 22

Advertising
background image

MPP300

EN - 20

32. To stop recording, press the GO/STOP key on the

instrument SOLAR300N and confirm with ENTER that
you want to stop recording.

33.

The display of SOLAR300N will show various
messages indicating the different phases of data
transfer to the main unit. The transferred data will be
saved automatically.

34.

After the automatic data transfer phase, the
instrument:

 Do not show any results if do not exist on the PV

installation a “stable irradiance” condition more
than the minimum irradiance threshold (see see
user’s manual of MASTER instrument) or all PRp
values are not valid (PRp > 1.15).

 Display the best performance values if during the

recording, the Irradiance values reached the “stable
condition and its values were higher than the
minimum irradiance threshold (see user’s manual of
MASTER instrument).


35. Press SAVE to save the obtained results. Pressing the

key will display the virtual keyboard for adding possible
comments. Further pressing the SAVE key will archive
the measure and the added comments and will go back
to the initial screen for a new measurement.

E x a m p l e o f a r e s u l t c o m b i n e d

w i t h M P P 3 0 0



Advertising