Table 4-5. calibration storage, Calibration storage -16 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.12 and higher User Manual

Page 150

Advertising
background image

4-16

BOP-1K 031014

ibration. Each time a CAL:SAV is executed, the values are saved in the Working (active) area.
At the same time, the values previously stored in Working are moved to Prior, and the values
previously stored in Prior are moved to Oldest. The values previously stored in Oldest are no
longer available. Table 4-5 illustrates calibration storage and the use of the CAL:DUMP? query
and CAL:COPY command.

TABLE 4-5. CALIBRATION STORAGE

COMMAND

WORKing

PRIor

OLDest

FACTory

MASTer

FIRst

1. CAL:SAVE

Cal 1 values

Factory cal.

Master cal.

First cal.

2. CAL:SAVE

Cal 2 values Cal 1 values

No Change

No Change

No Change

3. CAL:SAVE

Cal 3 values Cal 2 values Cal 1 values

No Change

No Change

No Change

4. CAL:SAVE

Cal 4 values Cal 3 values Cal 2 values

No Change

No Change

No Change

5. CAL:DUMP? FACTory;:CAL:COPY WORKing

Factory cal.

Cal 4 values Cal 3 values

No Change

No Change

No Change

6. CAL:DUMP? PRIor;:CAL:COPY WORKing

Cal 4 values

Factory cal.

Cal 4 values

No Change

No Change

No Change