Voltage and current parameter definitions -13 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.12 and higher User Manual

Page 79

Advertising
background image

BOP HIPWR 031014

3-13

a.

Use the ADJUST control to increase or decrease the main channel setting (e.g., volt-
age when the unit is in voltage mode). Start with the most significant digit of the desired
value, then use

T

to highlight the next digit. For fine adjustment press the ADJUST

control in while rotating the knob to modify the least significant digit.

b.

Enter the desired value on the keypad using the number keys. For example, to program
the BOP to 75.8V, press the following keys in order

75.8

then press ENTER. For

fine adjustment use

Y

, and

U

to modify the least significant digit. To correct the entry

before activation press the CLEAR key to set the value to zero and start over. When the
desired value is displayed, press ENTER. This causes the new value to appear at the
output and be applied to the load if the output is enabled.

TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS

Term

Definition

To modify

refer to PAR.

Local

Remote

+E

Onom

–E

Onom

The nominal (rated) output voltage of the unit determined by model; e.g. for
a BOP 36-28MG, ±E

Onom

is 36V.

N/A

N/A

+I

Onom

–I

Onom

The nominal (rated) output current of the unit determined by model; e.g. for
a BOP 36-28MG, ±I

Onom

is 28A.

N/A

N/A

+Voltage
–Voltage

Voltage mode only. Positive (+) and negative (–) output voltage values
established by keypad or remote command.
Range (+): 0 to +Voltage max
Range (–): 0 to –Voltage min

B.88

+Voltage max
–Voltage min

Voltage mode only. Maximum (positive) and minimum (maximum
negative) voltage that can be set.
Value (+): 0 to +E

Onom

Value (–): 0 to –E

Onom

3.3.4.1

B.90, B.91,

B.92, B.94

+Current Protect
–Current Protect

Voltage mode only. Defines maximum (+) current and Minimum (maximum
negative) (–) that unit can source or sink.
Range (+): +Current Protect min to +Current Protect max
Range (–): –Current Protect max to –Current Protect min

B.29,

B.30,

B.35, B.33

+Current Protect Max
–Current Protect Min

Voltage mode only. Maximum setting for +Current Protect and Minimum
(maximum negative) setting for –Current Protect.
Value (+): +Current Protect min to (1.01 x +Current max)
Value (–): –Current Protect max to (1.01 x –Current min)

3.3.4.2

B.37, B.38,

B.41, B.39

Minimum (box)
+Current Protect Min
–Current Protect Max

Voltage mode only. Minimum (positive) setting for +Current Protect and
maximum (maximum negative) setting for –Current Protect. Values of ±Cur-
rent Protect between +Current Protect Min and –Current Protect Max (near
zero) are not allowed.This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-3).

N/A

N/A

+Voltage Protect
–Voltage Protect

Current mode only. Maximum positive (+) and minimum (maximum
negative) (–) voltage that can appear at the output.
Range (+): +Voltage Protect min to +Voltage Protect max
Range (–): –Voltage Protect max to –Voltage Protect min

B.98, B.99,

B.104,

B.102

+Voltage Protect Max
–Voltage Protect Min

Current mode only. Maximum (positive) setting for +Voltage Protect and
Minimum (maximum negative) setting for –Voltage Protect.
Value (+): +Voltage Protect min to (1.01 x +Voltage max)
Value (–): –Voltage Protect max to (1.01 x –Voltage min)

3.3.4.2

B.106,
B.107,

B.110,

B.108