Chapter 9. Dial Plan Terminal Menu

61200266L1-1

ATLAS 810

PLUS

User Manual

9-11

»» Outgoing Number

Conversion

Write Security: 3 Read Security: 5
Defines the rules for converting as-dialed numbers into ISDN number type
and plan.

As dialed

Send digits provided as unknown number type.

ISDN - National pref

Convert to ISDN type, using the 10-digit national form if possible.

ISDN - Subscriber
pref

Convert to ISDN type, using the 7-digit subscriber form if possible.

ISDN - National
DMS Reserved pref

Send digits provided as National Number Type, DMS Reserved Numbering
Plan.

»» Strip MSD

Write Security: 3 Read Security: 5
Strips a selected quantity of the Most Significant Digits (MSD) of a dialed
number prior to being forwarded out of the port. For example, a Network
port set to accept all calls beginning with 9 (9$) and

Strip MSD

set to 1,

sends all digits toward the Network except the leading 9.

»» Netwrk Spec. Fac.-

Voice

Write Security: 3 Read Security: 5
(Network Specific Facility - Voice) Defines specific facility IEs to send to the
Network. Use this option if the customer has subscribed to a network spe-
cific facility service such as AT&T Megacom service. The facility request
sent can be different for voice calls versus data calls. A setting of

1RUPDO

indicates no special facilities have been subscribed.

»» Netwrk Spec.-Fac.

Data

Write Security: 3 Read Security: 5
(Network Specific Facility - Data) Defines specific facility IEs to send to the
Network. Use this option if the customer has subscribed to a network spe-
cific facility service such as AT&T Megacom service. The facility request
sent can be different for voice calls versus data calls. A setting of

1RUPDO

indicates no special facilities have been subscribed.

»» Called Digits

Transferred

Write security: 2; Read security: 5
Defines the number of digits to expect (choose from

1RQHñý7KUHHñý)RXUñ

and

$OO

). The default is All and would almost always be correct. If less than All

digits are sent, then the prefix is defined below. Use this option for PRI
switches that only send a portion of the called number (like DID).

When a 4ESS is configured, many installations will require the
national form where possible; this may also be the preferred form
in 10-digit calling areas.

Strip MSD

does not affect the

Call Accept

criteria. All of the

digits (including the MSDs that are subsequently stripped) are used
as Accept criteria.