KEW6305

KEW6305

Parameters to be saved

Parameters to be saved

The table below shows the parameters to be saved corresponding to each measurement range.
(Parameters to be saved are different depending on wiring systems.)

Manual saving : parameters in column 1 only

(except for max/ min/ avg of each parameter)

Auto-saving

: all parameters in column 1 & 2

Parameters to be saved

1

Voltage

(RMS)

Vi

: voltage of each phase

Vi max : max. Vi values

Vi min : min. Vi values

Vi avg : avg. Vi values

Current

(RMS)

Ai

: current of each phase

Ai max : max. Ai values

Ai min : min. Ai values

Ai avg : avg. Ai values

Active power

P

: total active power

Pi

: active power of each phase

P max : max. P value

Pi max : max. Pi values

P min : min. P value

Pi min

: min. Pi values

P avg : avg. P value

Pi avg

: avg. Pi values

Reactive power

Q

: total reactive power

Qi

: reactive power of each phase

Q max : max. Q value

Qi max : max. Qi values

Q min : min. Q value

Qi min

: min. Qi values

Q avg : avg. Q value

Qi avg

: avg. Qi values

Apparent power

S

: total apparent power

Si

: apparent power of each phase

S max : max. S value

Si max : max. Si values

S min : min. S value

Si min

: min. Si values

S avg : avg. S value

Si avg

: avg. Si values

Power factor

PF

: power factor of whole system PFi

: power factor of each phase

PF max : max. PF value

PFi max : max. PFi values

PF min : min. PF value

PFi min : min. PFi values

PF avg : avg. PF value

PFi avg : avg. PFi values

Frequency

f

: frequency of V1

f max : max. f value

f min

: min. f value

f avg

: avg. f value

Neutral

current

In

: current on neutral line

In max

: max. In value

In min

: min. In value

In avg

: avg. In value

2

Active energy

(consumption)

(regenerating)

(overall)

+WP

: total active energy (consumption)

+WPi

: active energy (consumption) of each phase

-WP

: total active energy (regenerating)

-WPi

: active energy (regenerating) of each phase

#WP

: total active energy (overall)

#WPi

: active energy (overall) of each phase

Apparent

energy

(consumption)

(regenerating)

(overall)

+WS

: total apparent energy (consumption)

+WSi

: apparent energy (consumption) of each phase

-WS

: total apparent energy (regenerating)

-WSi

: apparent energy (regenerating) of each phase

#WS

: total apparent energy (overall)

#WSi

: apparent energy (overall) of each phase

Reactive energy

(consumption) +WQ

: total reactive energy (consumption)

Demand value #DEM : total demand value

#DEMi : demand value of each phase

TARGET : target demand value

* i = 1, 2, 3

where, “max.” and “avg.” mean maximum and average values during an interval.