West Control Solutions N4400 User Manual

Page 23

Advertising
background image

CANCELLING JOIN, REPEAT OR END MARKERS

To cancel a Join, Repeat or End Marker:

(a) at the Fi nal Set point Value pa rame ter, press the Up and Down keys
si mul ta ne ously to pro duce a Dwell seg ment, or

(b) at the Seg ment Time/Ramp Rate pa rame ter, in cre ment the value to 0 or a
posi tive value.

8.5

USING JOIN, REPEAT AND END MARKERS AND CYCLING
PROGRAMS

By default, the Setpoint Programmer has eight programs, each 16 segments long (all 16
segments are active and, at the end of Segment 16 is an implicit End Marker). These
programs can be made shorter (using End Markers) or longer (by creating program
sequences with Join, Repeat and End Markers). The only limit to the size of a program
sequence is a maximum length of 121 active segments plus seven Join Markers plus one
End Marker (i.e. all eight programs joined to make one program sequence).

Segments follow a free format in that ramp or dwell can be followed by dwell or ramp,
completely as desired.

Consider two example programs:

To join the two programs to form a program sequence, change the End Marker of Program
1 to a Join Marker (Segment Time/Ramp Rate set to J02 - Join Program 2):

59215-8

Page 8-6

59215

Advertising