Operation 16, 1 front view 16, Front view 16 – West Control Solutions TB 45 Temperature Monitor User Manual

Page 16: Operation 16 - 20, Operation 5.1, Front view, 5 operation

Advertising
background image

.

5

Operation

5.1

Front view

1

Display line 1: process value or limit value LC

2

Display line 2: limit value LC / unit /
extended operating level/ error list

3

Operation mode “Temperature monitor with latched alarm”

4

Error list (2 x ô ), e.g.

Fbf. x

sensor fault INP. X

sht. x

short circuit INP. X

Pol. x

wrong polarity INP. X

Lim. x

limit value alarm

...

5

Increment key

6

Enter key to select extended operating level or error list

7

Status indicator LEDs
green:

limit value 1 OK

green blinking:no data exchange with bus coupler

(only on instruments with optional

system interface)

red:

limit value 1 active

red blinking:

instrument fault

8

Display elements, active as bars

9

Status of switching output LC active

0

Status of switching output OUT2 active

!

Decrement key

§

PC connection for the BlueControl engineering tool

6 + 5:

The error list can be reset by pressing this key
combination.

g

In the first LCD-display line the measured value or limit value is shown (parameterizable). The second
LCD-line normally shows the limit value LC. When changing over to the parameter setting, configuration or
calibration level and at the extended operating level, the parameter name and value are displayed
alternately.

+

§ : To facilitate withdrawal of the PC connector from the instrument, please, press the cable left.

Operation

16

Front view

TB 45