3 parameter level 41, Parameter 41, Parameter level – West Control Solutions TB 45 Temperature Monitor User Manual

Page 41: Rng.l, Rng.h, Temp, Inl.1 ( inl.2), Oul.1 ( oul.2), Inh.1 ( inh.2), Ouh.1 ( ouh.2)

Advertising
background image

8.3

Parameter level

µ Entrys marked with this symbol are selectable only with existing device-option.

Range rnG

Name

Value range

Description

rnG.L

-1999...9999

lower limit alarm for main alarm LC

rnG.H

-1999...9999

upper limit alarm for main alarm LC

Functions Func

Name

Value range

Description

tEmP

0...9999

probe temperature for O2- measurement

µ

Inputs InP.1 and InP.2

µ

Name

Value range

Description

InL.1

(

InL.2)

-1999...9999

Input value of the lower scaling point
Dependent on sensor type, the input values can be scaled to the display values at
parameter level. Specification of the input value of the lower scaling point is in
units of the relevant electrical quantity (mA / V / Ohm), e.g. 4 mA.

OuL.1

(

OuL.2)

-1999...9999

Display value of the lower scaling point
Dependent on sensor type, the input values can be scaled to the display values at
parameter level. The operator can change the display value of the lower scaling
point, e.g. 4 mA is displayed as 2[pH].

InH.1

(

InH.2)

-1999...9999

Input value of the upper scaling point
Dependent on sensor type, the input values can be scaled to the display values at
parameter level. Specification of the input value of the upper scaling point is in
units of the relevant electrical quantity (mA / V / Ohm), e.g. 20mA.

OuH.1

(

OuH.2)

-1999...9999

Display value of the upper scaling point
Dependent on sensor type, the input values can be scaled to the display values at
parameter level. The operator can change the display value of the upper scaling
point, e.g. 20 mA is displayed as 12 [pH].

t.F1

(

t.F2)

0...999,9

Filter time constant [s]
Each input is provided with a digital (software)low-pass filter for suppression of
process-dependent interference on the input leads. The higher the value, the bet-
ter the filter effect, but the longer the input signal delay.

E.tc1

(E.tc2)

OFF, 0...100

external cold junction compensation, range dependent of temperature unit

Limit values LC, Lim1 … Lim 3

Name

Value range

Description

LC

-1999...9999

Limit value LC. Limit value LC is the main function of the temperature monitor.

L.1

-1999...9999

Low limit value 1 (

L.1< -1999 = off)

Alarm is active when exceeding and reset with low limit value plus hysteresis.

H.1

-1999...9999

High limit value 1 (

H.1< -1999 = off)

Alarm is active when exceeding and reset with high limit value minus hysteresis.

HYS.1

0...9999

Hysteresis of limit value 1 / LC
Switching difference for high and low limit value. For limit alarm resetting, the value must
decrease by this value with high limit value and increase by this value with low limit value.

L.2

-1999...9999

lower limit 2 (

L.2< -1999 = off) (s.u.)

H.2

-1999...9999

upper limit 2

(

H.2< -1999 = off) (s.u.)

HYS.2

0...9999

Hysteresis of limit 2 (s.u.)

L.3

-1999...9999

lower limit 3 (

L.3< -1999 = off) (s.u.)

H.3

-1999...9999

upper limit 3

(

H.3< -1999 = off)(s.u.)

HYS.3

0...9999

Hysteresis of limit 3 (s.u.)

g

Resetting to factory setting (default)

r chapter 6.9 (page 32)

Parameter level

TB 45

Parameter level

41