2 code tables 14, 1 structure of configuration words (c.xxxx) 14, 2 instrument (fb no.: 0 type no.: 0) 14 – West Control Solutions KS 800 ISO1745 Interface Manual User Manual

Page 14: 2 instrument (fb no.: 0 type no.: 0), Code tables 5.2.1

Advertising
background image

5.2

CODE tables

5.2.1

Structure of configuration words (C.xxxx)

The configuration words mentioned in the following code tables are composed of several sections, which can

be transmitted only in common.

The data in the table must be interpreted as follows:

Example (C100): Code Descr. R/W Type Description

Range

71

C100 R/W INT

CFunc: Controller function

Wfunc: set-point function

(T,H)

(E)

0..xxyz

Description

CFunc

WFunc

Thousands

Hundreds

Ones

Range

x

x

z

00 ... 07

0...1

Example: continuous controller; standard controller;

set-point-cascade with offset

0 2 0 4

g

- For transmission of configuration words, see chapter page 29.

- Die Einstellmöglichkeiten der Konfigurationswörter entnehmen Sie der KS 800 Funktionsbeschreibung

(Best. Nr. 9499 040 49218)

5.2.2

INSTRUMENT (FB no.: 0 type no.: 0)

Function block ‘INSTRUMENT’ is used for classification of all data which are valid for the overall instrument.

Process data

General

(function no.: 0)

Code Descr.

R/W Type Description

Range

Rem.

01

Unit_State 1

R

ST1 Status 1

A

10

Block 13..18

R

Block

13

Write Error

R

INT Error during last write access

0, 100...127

Ä p. 11

14

Write Error Position R

INT Position of last write access error

0...99

15

Read Error

R

INT Error of last read access

0, 100...127

16

DPErr

R

INT Error message from DP-module

B

17

DPAdr_eff

R

INT Effectiv PROFIBUS adress

0 … 126

18

Type

R

INT Type no. of function block

0

20

Block 21...27

R

Block

21

HWbas

R

INT Basic HW options: module A, P

C

23

SWopt

R

INT SW options 1

D

24

SWcod

R

INT SW code no. 7th to 10th digit of 12NC

wxyz

E

25

SWvers

R

INT SW code no. 11th to 12th digit of 12NC

00xy

F

26

OPVers

1)

R

INT Operating version

27

EEPVers

1)

R

INT EEPROM version

31

OpMod

R/W INT Switch over unit to configuration mode (only after 1) 0

Switch over unit to on-line mode (only after 0)

1

Cancelation of configuration mode (only after 0)

2

32

Ostartg

R/W INT Self-tuning stop/start of all group controllers

0..1

33

UPD

R/W INT Acknowledgement of local data change

0..1

G

Function block protocol

9499 040 49411

14

1) Data are specified for future use (distinction of internal version).