35

IMPORTANT: The dryer and its individual shutoff valve must be disconnected from the gas

supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psig (3.5 kPa).

NOTE: The dryer must be isolated from the gas supply piping system by closing its individual

manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).

H. WATER SUPPLY CONNECTION FOR OPTIONAL SPRINKLER SYSTEM

If the dryer is equipped with the optional sprinkler system, a water supply of approximately 40 PSI (2.75 bars)
must be connected into the 1-inch N.P.T. sprinkler shutoff valve located on the left side of the dryer’s base.

I. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.

1. Turn on electric power to the dryer.

2. Make sure the loading doors are closed and the lint drawer is closed.

3. Press in “green” power button and it will illuminate.

4. Microprocessor controller (computer) system operational test -- to start the dryer:

a. Display will read “READY.”

b. Press “D” (preprogrammed) cycle key on the keyboard (touch pad).

5. The dryer will then start (i.e., blower, basket [tumbler] and heat).

6. The light emitting diode (L.E.D.) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.

NOTE: Press the “UP ARROW” to view the basket (tumbler) temperature at any time.

NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key. If the

temperature is above the Cool Down set point when the “STOP/CLEAR” is pressed, the
dryer will go into a Cool Down Cycle. If the “STOP/CLEAR” key is pressed again at
this point the cycle that was in progress will be canceled and returned to the “READY”
state. If the temperature is below the Cool Down set point the cycle that was in
progress will be canceled, and go into Wrinkle Guard Cycle.