Troubleshooting – American Dryer Corp. AD-310 Phase 7 Tilting User Manual

Page 64

Advertising
background image

60

SECTION XII

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY

and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR
CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY
EQUIPMENT per OSHA
(Occupational Safety and Health Administration)
STANDARDS.

The information provided will help isolate the most probable components associated with the difficulty described.
The experienced technician realizes, however, that a loose connection or broken/shorted wire may be at fault
where electrical components are concerned...not necessarily the suspect component itself. Electrical parts should
always be
checked for failure before being returned to the factory.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the

fuse being replaced. The information provided should not be misconstrued as a
handbook for use by an untrained person in making repairs.

WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A

QUALIFIED PROFESSIONAL or SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS

DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.

A. No Display...

1. “EMERGENCY STOP” (E-Stop) button pushed in.

2. Service panel fuses blown or tripped breaker.

3. Blown F2 (fuse 2) on microprocessor controller (computer) input/output (I/O) board.

4. Blown CB7 (Circuit Breaker) on right hand control panel.

5. Failed display board.

6. Failed communication cable.

7. Failed microprocessor controller (computer) I/O board.

8. Optional sprinkler circuit emergency relay is not engaged...

a.

Service panel fuse blown or tripped breaker.

b. Sprinkler circuit hi-limit has tripped.