American Dryer Corp. AD-310 Phase 7 Tilting User Manual

Page 56

Advertising
background image

52

2. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 880815

a. Upon completing installation of the

replacement DSI module, reestablish power
to the dryer.

b. Starting the drying cycle.

c. The ignition DSI module’s light emitting

diode (L.E.D.) indicator will light “red” for
up to approximately 1.5-seconds (prepurge
time).

d. The module’s indicator light will then turn

“green.” The gas valve will be energized
and the ignitor probe will spark for
approximately 8-seconds. The burner flame
should now be established.

e. With the burner flame on, remove the flame

sensor wire from the FS terminal of the DSI
module.

f. The burner flame must shut off and the

ignition module must lockout with the DSI
module’s indicator light “red.”

g. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h. The ignition module must proceed through the prepurge, with the indicator light “red,” the ignition trial

time of approximately 8-seconds, with the indicator light “green,” and then proceed to lockout with the
indicator light “red.”

i. Functional check of the DSI module is complete.

1) Replace the flame sensor wire from the FS terminal to the DSI module.

Advertising