23

and “NO” for non-latching. Use the

ENTER key to enter choice.

Note: “

RESET” function programmable for front panel key or

remote input, is used to reset the latched alarm.

h.

"SAFE" ("ALARM 1" ONLY) selects alarms 1 through 3 to be

in a safe mode (de-energizes on alarm) or standard (energizes on

alarm). Use

SELECT key to view “YES” for safe and “NO” for

standard. Use the

ENTER key to enter choice. Note: This is

used to determine what the alarms do when loss of power occurs

to meter. With "SAFE" selected alarm will turn on when power

fails.

i.

"FLASH" selects alarm to flash display when in alarm. Use

SELECT key to view “YES” for flash display and “NO” don’t

flash display. Use the

ENTER key to enter choice.

j.

“ENABLE” selects if set point is changeable in the run mode, or

just viewing a load.

2.

ANALOG OUTPUT

This setup menu programs the analog output/retransmission.

a.

"SOURCE" selects what the analog output will be based upon.

Use

SELECT key to view choices. Use ENTER key to enter

choice. After choice is entered then addition choices are entered.

1.

Selections are:

"CHAN 1"

Channel 1

a)

"GROSS"

gross value (default)

b)

"NET"

net value

c)

"PEAK 1"

peak 1 value

"CHAN 2"

Channel 2

a)

"GROSS"

gross value

b)

"NET"

net value

c)

"PEAK 1"

peak 1 value

"CHAN 3"

Channel 3

a)

"GROSS"

gross value

b)

"NET"

net value

c)

"PEAK 1"

peak 1 value

"DISPLY"

What ever is currently

selected

Advertising