add signaling-group 201 Page 1 of 1
SIGNALING GROUP

Group Number: 201 Group Type: sip
Transport Method: tls
IMS Enabled? n



Near-end Node Name: CLAN Far-end Node Name: SES
Near-end Listen Port: 5061 Far-end Listen Port: 5061
Far-end Network Region: 1

Far-end Domain: avaya.com


Bypass If IP Threshold Exceeded? n
Incoming Dialog Loopbacks: eliminate RFC 3389 Comfort Noise? n
DTMF over IP: rtp-payload Direct IP-IP Audio Connections? y
Session Establishment Timer(min): 3 IP Audio Hairpinning? n
Enable Layer 3 Test? n Direct IP-IP Early Media? n
H.323 Station Outgoing Direct Media? n Alternate Route Timer(sec): 6

5.6. Configure SIP Trunk

This section describes the steps for administering a trunk group in Communication Manager for
communication between Communication Manager and SIP Enablement Services. Enter the add
trunk-group <t
> command, where t is an unallocated trunk group and configure the following:

Group Type – Set the Group Type field to sip.
Group Name – Enter a descriptive name.

TAC (Trunk Access Code) – Set to any available trunk access code.

Signaling Group – Set to the Group Number field value configured in Section 5.5.

Number of Members Allowed value is between 0 and 255. Set to a value large enough

to accommodate the number of SIP telephone extensions being used.


Note: Each SIP call between two SIP endpoints (whether internal or external) requires two SIP
trunks for the duration of the call. The license file installed on the system controls the maximum
permitted.

add trunk-group 201 Page 1 of 21
TRUNK GROUP

Group Number: 201 Group Type: sip CDR Reports: y
Group Name: To SES COR: 1 TN: 1 TAC: 116
Direction: two-way Outgoing Display? y
Dial Access? n Night Service:
Queue Length: 0
Service Type: tie Auth Code? n

Signaling Group: 201
Number of Members: 10