Table 5-8: Measurement Results Registers

Register Description

Write Address

(Hex)

Read Address

(Hex)

X Axis Measurement (2)

24

A4

X Axis Measurement (1)

25

A5

X Axis Measurement (0)

26

A6

Y Axis Measurement (2)

27

A7

Y Axis Measurement (1)

28

A8

Y Axis Measurement (0)

29

A9

Z Axis Measurement (2)

2A

AA

Z Axis Measurement (1)

2B

AB

Z Axis Measurement (0)

2C

AC

Normally it is only necessary to send “A4

H

”, since the register value automatically

increments on the clock cycles such that after sending “A4

H

” all 3 bytes for the X axis

measurement would be clocked out, then the 3 bytes for the Y axis measurement, then the 3

bytes for the Z axis measurement. After these 9 bytes have been clocked out, the subsequent

output data has no relevance.

5.6 Troubleshooting and General Information

The RM3100 Evaluation Board incorporates several registers that can be used to help

troubleshoot the system or device. These include the Built-In Self Test (BIST) register, the

Handshake register, and the RevID register.

5.6.1 BIST Register (0x33)

The BIST register checks the status of the internal LR circuit oscillator. Write to the

BIST register by sending 0x33 followed by the BIST register values, and request a read

from the BIST register by sending 0xB3. The register contents are defined below.

Bit #

7

6

5

4

3

2

1

0

Value

STE

ZOK YOK XOK BW1 BW0

BP1

BP0

`