Specifications, Rm3100 evaluation board characteristics, Table 3-1: operating performance – PNI RM3100 Evaluation Board User Manual

Page 6: 3 specifications

Advertising
background image

PNI Sensor Corporation

Doc 1017252 r02

RM3100 Evaluation Board User Manual

Page 5 of 33

3 Specifications

3.1 RM3100 Evaluation Board Characteristics

Table 3-1: Operating Performance

1

Parameter

Cycle Counts

2

Units

50

100

200

Field Measurement Range

3

-800 to +800

T

Gain

20

38

75

LSB/ T

Sensitivity

50

26

13

nT

Noise

30

20

15

nT

Noise Density @ Max. Single-Axis Sample Rate

1.2

nT/ Hz

Repeatability over 200 T

15

8

8

nT

Hysteresis over 200 T

15

nT

Linearity over 200 T

0.5

%

Maximum Single-Axis Sample Rate
(divide by 3 for max. 3-axis sample rate)

1600

850

440

Hz

Single-Axis Average Current @ 24 Hz Sample

Rate (equivalent to 3-axis @ 8 Hz)

70

135

260

µA

Footnotes:

1. Specifications are typical and subject to change. Performance specifications established with 3.0

V supply voltage at room temperature.

2. The cycle count values (50 ,100, and 200) are user-configurable and set in the Cycle Count

Registers. See Section 5.1 for how to set the registers.

3. Field measurement range is defined as the monotonic region of the output characteristic curve.

Advertising