2 initiate a single measurement, 3 initiate continuous measurement mode, 4 read the measurement results – PNI RM3100 Sensor Suite User Manual

Page 43: Initiate a single measurement, Initiate continuous measurement mode, Read the measurement results, The i, A sample i

Advertising
background image

PNI Sensor Corporation

Doc 1017252 r03

RM3100 & RM2100 Sensor Suite User Manual

Page 42 of 45

5.8.2 Initiate a Single Measurement

The I

2

C transactions to initiate a single measurement on all 3 axes are given below.

START

MagI2C ADDRESS

RW ACK POLL REG. ADDRESS (N) ACK

DATA TO POLL REG (N)

ACK STOP

S

0

1

0 0

0 X X

0

0

0 0

0

0 0 0

0

0

0

0 1

1

1 0 0

0

0

0

P

From Host to MagI2C

From MagI2C to Host

After this transaction sequence the MagI2C will initiate a measurement sequence, and

this can run in the background. At the end of the measurement sequence the DRDY pin

is set HIGH and the Status Register will have a “1” in bit 7, indicating data is ready. The

MagI2C will be placed in Idle Mode.

5.8.3 Initiate Continuous Measurement Mode

A sample I

2

C transaction to initiate continuous measurement mode is given below.

START

MagI2C ADDRESS

RW ACK CMM REG. ADDRESS (N) ACK

DATA TO CMM REG (N)

ACK STOP

S

0

1

0 0

0 X X

0

0

0 0

0

0 0 0

0

1

0

0 1

1

1 1 0

0

1

0

P

From Host to MagI2C

From MagI2C to Host

In this example, the CMM register is set to initiate measurements on all 3 axes, and to set

DRDY to HIGH after all three measurements are made.

5.8.4 Read the Measurement Results

When the host is ready to read the Measurement Results registers, the following

transactions should occur. Note only the initial Measurement Results register address

needs to be sent, as the MagI2C automatically increments to the subsequent registers.

START

MagI2C ADDRESS

RW ACK

MX2 ADDRESS (N)

ACK STOP

S

0

1

0

0

0 X

X

0

0

0 0

1

0 0 1

0

0

0

P

From Host to MagI2C

From MagI2C to Host