Terminal block diagram











Measuring humidity or temperature only

Operation of the HF73 does not require both current loops to be closed. When using the HF73 to measure
either humidity only or temperature only, close only the loop that is being used.

Using the ROTRONIC HW4 software, any unused output of the HF73 can be disabled.

6.3.3

Grounding (all models)

We generally recommend grounding the (-) side of the power supply, especially if the electronics will be
subjected to a low humidity environment (35 %RH or less).






Terminals

Description

K1-1: OUT1

Relative humidity or dew point (+)

K1-2: OUT2

Temperature output (+)

K1-3: GND

Ground (tied with other GND)

K2-1: PWR

Power supply: 15…40 VDC (+)
or 12…28 VAC (Phase)

K2-2: GND

Power supply (-) or neutral
(tied with other GND)