Sterlco SGBD Series Batch Gravimetric Blenders User Manual

Page 73

Advertising
background image

Bulletin Number

Chapter 7: Appendix

73 of 101

Annex B Information

The following design information is provided for your reference:

1. No modifications are allowed to this equipment that could alter the CE compliance
2. Ambient temperature:

40 degrees Celsius – Maximum (104 degrees

Fahrenheit)

3. Humidity range:

50% relative humidity

4. Altitude:

Sea

level

5. Environment:

Clean, dust-free and non-explosive

6. Radiation:

None

7. Vibration:

Minimal,

i.e.

machine

mounting

8. Special installation requirements:

Clean, dry compressed air 1 cfm @ 60 psi (1.7

m³/hr @ 4.14 bar)

9. Allowable voltage fluctuation:

+/- 10%

10. Allowable frequency fluctuation:

Continuous

+/- 1%

Intermittent +/-

2%

11. The addition of an auger feeder (RAM option) for regrind will increase the electrical

supply requirements of a standard blender.

12. Nominal supply voltage:

120/1/60 or 220/1/50/60 (Verify on serial number tag)

13. Earth ground type:

TN (system has one point directly earthed through a
protective conductor)

14. Power supply should include a neutral power connection.
15. Over-current protection is supplied in the blender, but additional protection should be

supplied by the user.

16. The plug on the power cord serves as the electrical disconnect device.
17. Unit is not equipped with three-phase motors.
18. N/A
19. Blender is not equipped with local lighting.
20. Functional identification
21. Blender is equipped with a CE mark
22. Blender is supplied with an operating manual in the language of the destination

country.

23. Cable support may be required for power cord, depending on final installation.
24. No one is required to be in the interior of the electrical enclosure during the normal

operation of the unit. Only skilled electricians should be inside the enclosure for
maintenance.

25. Doors can be opened with a screwdriver, but no keys are required.
26. Two-hand control is not required or provided.
27. All blenders should be moved around and set in a place with a lift truck or equivalent.
28. There are no frequent repetitive cycles that require manual control

⎯repetitive

functions are automatic while the blender is operating.

29. An inspection report detailing the functional test is included with the blender.
30. The machine is not equipped with cableless controls.
31. Color-coded (harmonized) power cord is sufficient for proper installation.

Advertising