Sterlco BP800 Series Granulators User Manual

Page 35

Advertising
background image

800 Series beside-the-press

Chapter 6: Troubleshooting

35 of 43

Electrical Problems

Problem

Possible Cause

Possible Remedy

Machine stops for no

apparent reason

Safety switch has stopped
power

Check that the knobs that
operate the safety switch are
tightened

Electric motor does not start

No power

Check fuses

Overload failure

Check amperage of electric
motor

Safety switch not working

Check and replace

Cutting chamber too full

Empty cutting chamber

Motor starts but does not

speed up or take a load

Excessive drive belt tension

Check belt tension and adjust

Motor connected to power
source incorrectly

Reconnect correctly

Defective starter winding

Check current in each phase.
If substantial difference
between phases, contact
motor manufacturer

Motor starts, but does not

gain speed

Bearing excessively worn

Replace bearings

Cutting chamber full

Empty cutting chamber

Advertising