Bed Knives
We recommend that the same screws and washers be re-used only when the bed knives have
been repositioned or re-ground. When blunt knives are discarded and replaced with new
knives, use new screws and washers. This will reduce the risk of screw failure due to their
overstretching. Screws and washers must be replaced with the type specified in the Spare
Parts List. Use the following procedure to replace or adjust the bed knives:

1. Access the cutting chamber as directed in Section 3-4 on page 20.

2. Loosen the lock nuts on the bed knife adjusting screws and back off screws.

3. Loosen and remove the bed knife bolts and lift the upper shield, removing it from the

cutting chamber.

4. Remove the bed knives.

5. Before installing and adjusting the bed knives, check all rotor knives to make sure

they are properly seated on the rotor and securely fastened.

6. Place the downstroke bed knife and its shield in place and hand-tighten the knife

bolts to hold them firmly to the knife seats.

7. Using the push and pull screws to set the knife clearance to 0.005” to 0.008” for most

materials; 0.014” to 0.016” for solid wall pipe with 0.187” wall thickness or greater.
The clearance should be measured with a feeler gauge at the ends of the knife, by
rotating the rotor sheave backwards by hand. The clearance is slightly greater at the
center of the knives.

8. Adjust the shield using its push and pull screws so that its front edge is within 1/32”

of the bed knife edges.

9. Tighten the bed knife bolts to 95 ft. lb. (128 Nm).

10. Repeat steps 6 through 9 for the upstroke bed knives.