2 electrical connections – Sterlco SLS Series Light Duty Shredder User Manual

Page 22

Advertising
background image

GRN4-600

Chapter 3: Installation

22 of 50

Suspended load! Falling loads can cause serious injury or death! Only use
a crane or forklift appropriate for the weight and dimensions of the load.
Use suitable means to stop and pay attention to the center of gravity. Do
NOT step under the suspended load. Wear a safety helmet in addition to
the basic protective gear.

Overturning or falling machine! Serious injury or death can result! In case
that the granulation will be placed erect over a pit, on a frame, or on a
platform, the machine MUST be secured by placing mounting screws
though the holes on the mounting pads (see assembly drawing).

3-2 Electrical Connections

Electrical connections should only be made by qualified electricians!

Voltage, current, frequency, and protection are marked on the type plate. The voltage
tolerance is +/- 10%.

For machines that are not pre-wired, the electrical connection is to be carried out in
accordance with the enclosed wiring diagram in the terminal box. When performing this
task, it is important to follow the regulations of the local electricity authority. The
required cable cross-section is determined according to the rated capacity of the units.
The wiring schematics are located in the control panel.

NOTE:

Alterations to the wiring diagrams require the approval of the
manufacturer. Failure to obtain approval will result in the termination of
all guaranteed claims.

DANGEROUS VOLTAGE. Touching live parts can lead to serious injury or
death! Trained electricians may only carry out all work relating to the
electricity of the machine. Observe the currently effective EMC regulations.

Caution must be taken to prevent electrical shock when operating certain
equipment. Installation, service, alterations, and/or modifications must
only be done by qualified personnel and with a high regard for safety.
Failing to conform to the requirements could result in bodily injury, costly
damage, or death!

Connection of Emergency Stop Button

The machine must only be operated with installed Emergency Stop buttons. If the
Emergency Stop buttons are not installed prior to delivery, one Emergency Stop button
must be installed at the control cabinet and a second one at the grinding material in-feed.

NOTE:

The control panel with the switches and Emergency Stop button should be
installed near the machine; the distance should not exceed 16 ft (5 m). The
connecting cables between the control panel and machine must be protected
against damage. If the control panel cannot be installed according to these
rules, an additional Emergency Stop button must be installed on the
machine