Problem

Possible Cause

Possible Remedy

Rotor does not grip bulky

material.

Knife condition

• Check and sharpen in

needed, according to the
instructions in this manual.

Protruding bed knife.

• Consult customer service.

Knives not aggressive enough.

• Fit underlay plates below the

knife holders.

Overheating grinding material.

See first five causes for

“Machine blocks or switches

itself off”

• See first five remedies to

“Machine blocks or switches
itself off”

Knives sharpened wrongly.

• Modify knife finish after

consulting customer
service
.

Material rubs against the

housing wall.

• Fit anti-winding device.

Insufficient cooling.

• Fit rotor cooling.

Unusual vibrations.

Rotor out of balance.

• Weight knives, balance rotor.

Bearing damage.

• Check bearings and replace if

needed.

Anti-vibration pads defective

• Check mounting pads and

renew if needed.

Extreme cutter wear.

Bearing damage.

• Check bearings and replace if

needed.

Knife finish.

• Check knife and

sharpen/replace if needed.

Wrong cutting gap.

• Check cutting gap and set

according the instructions in
this manual.

Foreign matter.

• Fit feed device with metal

detector.

Bearings too hot.

Too much grease.

• Reduce amount of grease.

Rubbing on housing sealing

ring.

• Check sealing ring, oil, or

replace.

Bearing damage.

• Check bearings and replace if

needed.

No grease in bearing.

• Lubricate bearing.

Cutting gap alters during

operation.

Knife mounting screws not tight.

• Re-tighten using torque

wrench in accordance with
this manual.

Screw fatigue.

• Fit new screws.

Washers are deformed.

• Insert new washers.

Knife holder surface is

deformed.

• Insert new knife holders.

Support surfaces are dirty.

• Clean and re-dust surfaces.

Threads in housing are worn.

• Fit new brushes in housing.

Advertising