Chapter 5: Maintenance

29 of 50

NOTE: Unsuitable lubricant, lubricant deficiency, excessive lubricant, or impurities

in the lubricant lead to overheating and extreme wear of the bearings.

Lubrication intervals

Use the following table to determine when to check and replace the lubricant.

Shift Operation

When to Replace

When to Check

One shift operation.

Every 18 months.

Monthly.

Two shift operation.

Every 9 months.

Monthly.

Three shift operation.

Every 6 months.

Monthly.

Checking lubricant quality

When determining whether a lubricant needs to be replaced, check for the following:

• Change in consistency.

• Discoloration.

• Degree of soiling.

Replacing or refilling lubricant

Fill the bearings uniformly with grease until all operating surfaces are well

greased.

A lubricant quantity of 1/3 to 1/2 of the bearing volume per bearing is

required. If too much grease is used, the lubricant will become unusable due
to excessive temperature.

Only one type of grease must be used. Mixing different types of grease

together is prohibited. The bearings are filled at the factory with lithium
base saponification roller bearing grease F3.

Use the “List of lubricants” to determine which lubricants from which

manufacturers to use.

Refilling lubricant

The grease travels through the circulating grooves and bores via lubrication nipples into
the interior of the bearing. The greasing quantity is 2 oz. (60g) to 3.5 oz. (100g) roller
bearing grease F3 per bearing.

Grease
nipple

Advertising