10

6. Cancelling Programmes

Any ON/OFF programme can be cancelled by clearing its ON and OFF time.

Follow step 5 and when into the ON or OFF programme to be cancelled press

the <Change> button until the hour digits show --:

then press the <Program> button to clear the

programme. The display will show the hour and

minute digits and ON or OFF flashing.

(Note: Monday shown as an example of days set).

Self Cancelling Override

To change the output status from ON to OFF or vice versa during normal operation

press the <Change> button. The output status will change and indicate override is in

operation by flashing.

1 2 3 4 5 6 7

Specifications

1. Confirms to latest directives.
2. Contacts:

Silver Cadmium Oxide. Single pole change over.

3. Permissible Loads: 16A Resistive

6A

At 0.4 power factor inductive

10A Filament lamps

*500W Fluorescent lighting with or without power factor

correction capacitors (4μF per 65W tube)

1 h.p. Motor

For other loads refer to Technical Service on 020 8450 0515

*This load with power factor correction capacitors is not

recommended for normally closed contacts.

4. Panel Cut Out:

67mm square with 2.5mm radius corners.

5. Battery Back-up: 1000 hours by factory fitted rechargeable battery.
6. Operating ambient temperature: -10°C to 40°C. Upper limit can be

increased for loads less than 16A –

refer to Technical Service.

7. Operating Voltage:

220 – 240V AC 50Hz.