Programme review, Initiating programme mode, Cancelling programmes – Timeguard EL17 User Manual

Page 7: Self cancelling override

Advertising
background image

26

iii

Press <Program> button once – the first ON time is

now set and display shows ready for the first OFF

programme time.

iv

Now set the hrs and minutes as before.

v

Repeat steps i to iv to set the remainder of the 3 ON/OFF times as required.

Note: Any unused ON/OFF programme should be skipped until the

display shows normal operating mode. Do not programme ‘0’s into

unused programmes.

IMPORTANT After setting a clock time which falls within a programmed ON

period, the unit will not switch ON. Use the override facility to switch unit ON.

After this the unit will operate normally to the programmes set.

4. Programme Review

To fast review the set programmes or for quick exit to normal

operating mode – press and hold the <Program> button.

5. Initiating Programme Mode

This can be initiated any time during the normal operating mode.

Press <Program> button and the Clock symbol, hrs and minutes symbols

on the display will flash – this is review mode. If any change to programmes

is required press <Change> button to initiate programme mode and then

follow steps 2 and 3.

6. Cancelling Programmes

Any ON/OFF programme can be cancelled by clearing its ON and OFF time.

Follow step 5 and when into the ON or OFF programme to be cancelled press

the <Change> button until the hour digits show --:

then press the <Program> button to clear the

programme. The display will show the hour

and minute digits and ON or OFF flashing.

Self Cancelling Override

To change the output status from ON to OFF or vice versa during normal operation

press the <Change> button. The output status will change and indicate override is in

operation by flashing.