UEi Test Instruments C75OILKIT User Manual

Page 8

Advertising
background image

C75-MAN

P. 7

Printing A Test
During combustion tests the analyzer can print data on request. With
the analyzer showing the data, briefly press the “PRINT“ button until
PRINTING” is displayed.

The standard printout is:

NOTE: Printouts of stored
readings will also include
the TEST NO. below the
header.

SMOKE area on printout
is for adding data from
manual test.

M a i n t e n a n c e

Periodic Service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the instrument. This could alter the protection from
personal injury this meter provides to the operator. Perform only those
maintenance tasks that you are qualified to do.

These guidelines will help you attain long and reliable service from your
meter:

• Calibrate your instrument annually to ensure it meets original

performance specifications

• Keep your instrument dry. If it gets wet, wipe dry immediately.

Liquids can degrade electronic circuits

• Whenever practical, keep the instrument away from dust and

dirt that can cause premature wear

• Although your instrument is built to withstand the rigors of daily

use, it can be damaged by severe impacts. Use reasonable caution
when using and storing the meter

Cleaning
Periodically clean your instruments case using a damp cloth. DO NOT
use abrasive, flammable liquids, cleaning solvents, or strong detergents
as they may damage the finish, impair safety, or affect the reliability of
the structural components.

Emptying and Cleaning the In-line Water Trap
The in-line water trap should be checked and emptied on a regular
basis. Water vapor will condense in the probe line, which may cause the
water trap to fill suddenly if the probe is moved. Care should be taken
at all times.

Carefully remove the rubber plug from the bottom of the water-trap
housing. Dispose of the condensate in a suitable drain, care must be
taken as it could be acidic.

UEI C75

16 character header
16 character header

503 644 8723

Date: 06-26-02
Time: 14:27

Fuel

NATU

GAS

O2

%

20.9

CO2

%

0.0

CO*

PPM

00

COaf*

PPM

00

FLUE

˚F

----

AMB

˚F

----

NETT

˚F

----

EFF%

(G)

----

LOSSES**

%

----

XAIR

%

----

SMOKE................................................................