Version 3.10E DAS Release Notes

21

21 Dec 2001

Corrections in DAS 3.10E

Addressed Problem Logs

Table 5

Problems solved with DAS 3.10E

Ticket

Number

Description

ET60330

"Cleanpool with 16 chars doesn't work". There is a
bug with incorrect setting of field value in AMU
telegram, which will be fixed.

In dasadmin "scr_insert" command another aci
function with a larger buffer size for volsers can
be used. The old aci function (aci_insert()) might
have a problem with large EIF and double-sided
(optical) volsers.

ET56507

"DAS/ACI timeout to 1st server when network is
down". The ability of preliminary testing of
connection with DAS server has been added. If
DAS/2 and ACI clients will be started with the
PORT_PING=<port> environment variable set
then this ability will be activated.

ET33777

"Eject has limited number of volsers".
"eject2" command in dasadmin has a limited buffer
size for volsers (100 bytes).
Now the "eject3" command is similar to "eject2" but
has a buffer size of 512 bytes.

PR97

"Mount failed after issued PINVT". There is a bug
in the DAS code, related to improper handling of
RPC task number. Will be fixed.

"Scr_set command works wrong". There is a bug
causing improper handling of media types in the
"scr_set" branch. This prohibited users from
inserting cartridges in scratch pool if the use count
of cartridges was not equal to zero.

PR82

"DAS:allocv: The manual says that a check of the
Volser in the given range will be made as to one is
available or mounted". DAS doesn't check the
availability of the requested volser and could
return a positive answer for a mounted volser. Will
be fixed.