American Dryer AD-120ES User Manual

Page 15

Advertising
background image

11

1. LEVELING DRYER

a. To level dryer, place 4-inch square metal shims (refer to illustration above) or other suitable material

under the base pads. It is suggested that the dryer be tilted slightly to the rear.

2. If more headroom is needed when moving dryer into position, the top console (module) may be

removed.

a. To remove top console (module)

1) Disconnect the ground wire (A) at the Rear Upper Left Hand Corner of Dryer.

2) Remove the six (6) set of nuts and washers (B) holding the console (module) to base.

3) Open the control door/control panel and disconnect the white 15-pin plug connector (C in the

illustration below) located in the base of the control box.

4) Disconnect white plug connector located outside backside of the control box (provides power to

heat circuit).

5) Lift the console (module) off of the dryer base.

IMPORTANT: The dryer must be transported and handled in an upright position at all times.

Advertising