4. Grounding

Grounding (earth) connections must be provided and installed in accordance with state and local codes. In
the absence of the codes, grounding must conform to applicable requirements of the National Electric
Code ANSI/NFPA NO.70LATEST EDITION, or in CANADA, the Canadian Electrical Codes Parts 1 &
2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at
the location service panel.

NOTE: A grounding connection (terminal lug) is provided in the dryer's electrical service/relay

box at the rear.

For added personal safety, when possible, it is suggested that a separate ground wire (sized per local codes)
be connected from the ground connection of the dryer to a grounded cold water pipe.

DO NOT ground to

a gas or hot water pipe. The grounded cold water pipe must have metal to metal connections all the way to
electrical ground. If there are any non-metallic interruptions, such as a meter, pump, plastic, rubber, or
other insulating connectors, they

must be jumped out with no. 4 copper wire and securely clamped to bare

metal at both ends.

IMPORTANT: For personal safety and proper operation, the dryer must be grounded. For

proper operation of the microprocessor (computer), an earth (zero) ground

is

required.

NOTE: Grounding via metallic electrical conduit (pipe) is not recommended.