Verification, Verification without an upstream device, Verification with an upstream device – ADC Campus-RS Remote User Manual

Page 12: Erification

Advertising
background image

Installation

152-402-145-02, Issue 2

6

June 16, 2000

H2TU-R-402

V

ERIFICATION

Verification without an Upstream Device

Verify that the H2TU-R powers up. The following should occur:

The front-panel ALM LED is a steady red.

The LOOP LED is flashing green.

If receiving a DS1 signal, one of the DS1 framing LEDs (ESF or SF) and one of the DS1 line code LEDs
(B8ZS or AMI) is a steady green.

Verification with an Upstream Device

1

Verify that the H2TU-R powers up.

The front-panel ALM LED is a steady red.

The LOOP LED is flashing green.

If receiving a DS1 signal, one of the DS1 framing LEDs (ESF or SF) and one of the DS1 line code LEDs
(B8ZS or AMI) is a steady green.

2

Verify that the H2TU-R attempts to communicate with an upstream device (LOOP LED is flashing green).
One of the following occurs:

If an upstream device is successfully identified and the HDSL2 loop synchronizes, the LOOP LED lights
a steady green.

If upstream devices are not successfully identified, the H2TU-R continues to attempt communication
(LOOP LED flashes green) until an upstream device is detected.