Appendix b - functional operation, Timing, H2tu-r-402 list 4e block diagram – ADC Campus-RS Remote User Manual

Page 40: B - f, Ppendix, Unctional, Peration, Iming

Advertising
background image

Appendix B - Functional Operation

152-402-145-02, Issue 2

34

June 16, 2000

H2TU-R-402

A

PPENDIX

B - F

UNCTIONAL

O

PERATION

ADC HDSL2 technology provides full-duplex services at standard DS1 rates over copper wires between an
H2TU-C and an H2TU-R, which comprise one HiGain HDSL2 system. HiGain HDSL2 systems use ADC
Overlapped PAM Transmission with Interlocking Spectra (OPTIS) transceiver systems to establish full-duplex,
1.552 kbps data channels between the remotely located H2TU-R-402 List 4E and an H2TU-C.

A block diagram of the H2TU-R-402 List 4E is shown in

Figure 25

.

The H2TU-R-402 List 4E power supply converts the 90 to 200 Vdc power that is received on the simplex pairs to
voltage and currents required by the remote unit circuitry.

Figure 25.

H2TU-R-402 List 4E Block Diagram

T

IMING

The low-loop wander (0.3 UI max) of an H2TU-R-402, when used with a compatible line unit, allows the circuit
to be used in all critical timing applications, including those that are used to transport Stratum 1 timing.

HDSL 2

XCVR

Microprocessor

Protection

Protection

Factory use only

BRG

Tip

Ring

Tip 1

Ring 1

BRG

OUT (RCV)

49

55

IN (XMT)

5

15

13

20

7

Ring

Tip

Framer

Loopback

CLOC

NREM

Circuit
Ground

17

Chassis Ground

1

+

Power
Supply

DS1 OUT
(RCV)

HDSL2

HDSL2 Span

DS1 IN
(XMT)

35

-

48V IN

27

Advertising