A2lb test procedures, Addressable repeater loopback commands (a2lb) – ADC Campus-RS Remote User Manual

Page 34

Advertising
background image

Loopback Operation

152-402-145-02, Issue 2

28

June 16, 2000

H2TU-R-402

A2LB Test Procedures

Using the codes listed in

Table 11

, a network tester can activate NLOC, NRG or NREM loopbacks (or SMJK, if

enabled). A tester at the customer premises can activate CLOC, CRG, or CREM loopbacks.

To perform the A2LB test procedures:

1

Send the inband Arming and NI LPBK code 11000 to the H2TU-R-402 for at least 5 seconds.

2

Monitor the output of the H2TU-R-402 for the return of the pattern. Return of the pattern indicates one of the
following:

The H2TU-R has looped up (if the SMJK Loopback option is enabled)

An external NID has looped up (if the SMJK Loopback option is disabled), and the H2TU-C and
H2TU-R have been armed.

3

Verify, if possible, that the H2TU-R LBK LED is either flashing yellow at 4-second intervals (indicating that
the system is armed), or is a steady yellow (indicating that it is both armed and in SMJK loopback). The
H2TU-C Status LED also flashes yellow when the system is armed.

Table 11.

Addressable Repeater Loopback Commands (A2LB)

Name

Description

Binary Code

(a)

(Hexadecimal Equivalent)

(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10

-3

BER on the facility.

The entire arming and loopback sequence can also be initiated at the remote H2TU-R location.

ARMING or NI LPBK (inband)

Arming code

11000-11000 ...

ARMING or NI LPBK (ESF Datalink)

Arming code

1111-1111-0100-1000 (FF48)

IR LPDN or DISARM (inband)

Disarming code

11100-11100 ...

IR LPDN or DISARM (ESF Datalink)

Disarming code

1111-1111-0010-0100 (FF24)

IOR LPBK (NLOC and CREM)
230-232 bit errors
229-231 bit errors

(b)

(b) The H2TU-R identifies CREM (and the H2TU-C identifies NLOC) with 231 bit errors, including the frame bits. When framed

data is being sent in the Auto framing mode, the number of the 231 bit errors detected by the test set varies from 229 to 231,
depending on whether or not the test set counts frame errors as bit errors and on the number of frame bits contained in the
block of 231 error bits. The H2TU-R and H2TU-C generate this bit pattern in a series of discontinuous bursts containing 20-bit
errors each, including frame bits. Those test sets that do not count frame error bits as data bit errors will indicate fewer bits
than the H2TU-R and H2TU-C transmit for a CI and NI loopback.

H2TU-C loopup

1101-0011-1101-0011 (D3D3)

IR LPDN

Loopdown (H2TU-C, H2RU, or
H2TU-R)

1001-0011-1001-0011 (9393)

IR QUERY LPBK

Query loopback

1101-0101-1101-0101 (D5D5)

IR ALTERNATE QUERY LPBK

Alternate query loopback

1101-0101-1110-1010 (D5EA)

TIME-OUT OVERRIDE

Loopback time-out override

1101-0101-1101-0110 (D5D6)

FAR END NI ACTIVATE

Unblock AIS

1100-0101-0101-0100 (C554)

IOR POWER DOWN (H2TU-C)

(c)

(c) The IOR Power Down code must remain present for the duration of the powerdown mode. When this code is removed, the

HiGain HDSL2 system returns to its normal unlooped and unarmed state.

Removes HDSL2 line power

0110-0111-0110-0111 (6767)

If the Arming code is not returned after 5 seconds, the system may be armed but there is no
active loopback.