3.5.4 Ship Settings (User Password Protected)


After a new User Password has been set, the Ship Settings may be input. The Ship Settings are
usually only set once, upon NAUTICAST initial operation.

A selection is made with the cursor buttons [Up]

or [Down] for input field selection. The category

“ShipType” is equipped with default settings, which can be selected by pressing the [Left] or [Right]
buttons.

NOTE: The default password from the factory is mentioned on your AIS display at the
protection foil. (see Appendix 7.2 for password information).
Before entering Ship Settings for initial NAUTICAST operation, it is advised to configure the
User Password in:

Menu 5:

Configuration

Submenu 1: Change User Password

After the User Password has been set, Ship Settings may be input.

Dynamic Keys: Input of Ship Settings

[M5] [Save]

Confirm Data Input [M8] [Back]

Return to Main
Menu


N48^12' E 16^26' |1> N/A|2> N/A|3> N/Anm

************ Ship Settings *************

Call Sign:SO52 /\ +

ShipName :SOLAS 52 / \|

Ref.Points ext int | |

A: 170m 171m | A

B: 30m 29m | |

C: 15m N/A | +--|

D: 15m 30m | | B

Len (A+B): 200m 200m | | |

Beam(C+D): 30m 30m +-C-+D-+

Ship Type: N/A or no ship

>>> DATA OK. PRESS M5 TO SAVE DATA <<<

----------------------------------------